Deployment Standards

Our Deployment Standard Documents are available in both Adobe Acrobat and Autocad drawing formats. Please click either the Acrobat or AutoCAD icon that corresponds to the deployment standard document you require.

You will need to login before you can download the following items. If you do not already have a Customer Account, please take this opportunity to complete a Customer Account.

Numbering Info
0xxxxx-0 - General Details, Applicable To All
0xxxxx-1 - Single Cable VDC (VDC1)
0xxxxx-4 - Four Cable VDC (VDC4)
0xxxxx-7 - Seven Cable VDC (VDC7)
   
2000 Series - Hard Infrastructure: 2000 - Asphalt
02005-1 VDC1 Asphalt Pavement Crossing W/Coldpatch & Hot Sealant Backfill (@120mm Or 5")
02005-4 VDC4 Asphalt Pavement Crossing W/Coldpatch & Hot Sealant Backfill (@120mm Or 5")
02008-1 VDC1 Asphalt Pavement Crossing W/Coldpatch Backfill (@120mm Or 5")
02008-4 VDC4 Asphalt Pavement Crossing W/Coldpatch Backfill (@120mm Or 5")
02009-1 VDC1 Asphalt Pavement Crossing W/Coldpatch & Hot Sealant Backfill (@230mm Or 9")
02009-4 VDC4 Asphalt Pavement Crossing W/Coldpatch & Hot Sealant Backfill (@230mm Or 9")
02012-7 VDC7 Asphalt Pavement Crossing W/Coldpatch & Hot Sealant Backfill (@305mm Or 12")
   
2000 Series - Hard Infrastructure: 2100 - Concrete
02105-1 VDC1 Back Of Curb W/Coldpatch, Limestone (@100mm Or 4")
02105-4 VDC4 Back Of Curb W/Coldpatch, Limestone (@100mm Or 4")
02106-1 VDC1 Concrete Sidewalk & Median W/Coldpatch, Limestone (@100mm Or 4")
02106-4 VDC4 Concrete Sidewalk & Median W/Coldpatch, Limestone (@100mm Or 4")
02108-1 VDC1 In Paving Bricks
02108-4 VDC4 In Paving Bricks
2000 Series - Hard Infrastructure: 2200 - Mixed Medium
02205-1 VDC1 Asphalt-Concrete Pavement Crossing W/Coldpatch & Hot Sealant Backfill (@120mm Or 5")
02205-4 VDC4 Asphalt-Concrete Pavement Crossing W/Coldpatch & Hot Sealant Backfill (@120mm Or 5")
02206-1 VDC1 Asphalt-Concrete Pavement Crossing W/Coldpatch Backfill (@120mm Or 5")
02206-4 VDC4 Asphalt-Concrete Pavement Crossing W/Coldpatch Backfill (@120mm Or 5")
02207-4 VDC4 Asphalt-Concrete Pavement Crossing W/Coldpatch & Hot Sealant Backfill (@230mm Or 9")
   
3000 Series - Soft Infrastructure: 3000 - Soil
03001-1 VDC1 Back Of Walk In Soil (@230mm Or 9")
03001-4 VDC4 Back Of Walk In Soil (@230mm Or 9")
03002-1 VDC1 Back Of Curb In Soil (@230mm Or 9")
03002-4 VDC4 Back Of Curb In Soil (@230mm Or 9")
03003-1 VDC1 In Soil (@230mm Or 9")
03003-4 VDC4 In Soil (@230mm Or 9")
03004-4 VDC4 In Soil (@457mm Or 1'-6")
03007-1 Crossing Existing Route W/New VDC1 Route In Soil (@230mm Or 9")
03007-4 Crossing Existing Route W/New VDC4 Route In Soil (@230mm Or 9")
   
4000 Series - Entries: 4000 - VDC To Ftt Clamp To Entry
04001-1 VDC1 In Asphalt To Ftt Clamp With Unexposed Core Above Grade Entry (@120mm Or 5")
04001-4 VDC4 In Asphalt To Ftt Clamp With Unexposed Core Above Grade Entry (@120mm Or 5")
04002-1 VDC1 In Asphalt To Ftt Clamp With Wall Cut Above Grade Entry (@120mm Or 5")
04002-4 VDC4 In Asphalt To Ftt Clamp With Wall Cut Above Grade Entry (@120mm Or 5")
04003-1 VDC1 In Asphalt To Ftt Clamp Below Grade Entry (@120mm Or 5")
04003-4 VDC4 In Asphalt To Ftt Clamp Below Grade Entry (@120mm Or 5")
04004-1 VDC1 In Asphalt To Ftt Clamp With Exposed Conduit Above Grade Entry (@120mm Or 5")
04004-4 VDC4 In Asphalt To Ftt Clamp With Exposed Conduit Above Grade Entry (@120mm Or 5")
04009-1 VDC1 In Asphalt To Ftt Clamp With Exposed Conduit Above Grade (@120mm Or 5")
04009-4 VDC4 In Asphalt To Ftt Clamp With Exposed Conduit Above Grade (@120mm Or 5")
04101-1 VDC1 In Concrete To Ftt Clamp With Unexposed Core Above Grade Entry (@100mm Or 4")
04101-4 VDC4 In Concrete To Ftt Clamp With Unexposed Core Above Grade Entry (@100mm Or 4")
04102-1 VDC1 In Concrete To Ftt Clamp With Wall Cut Above Grade Entry (@100mm Or 4")
04102-4 VDC4 In Concrete To Ftt Clamp With Wall Cut Above Grade Entry (@100mm Or 4")
04103-1 VDC1 In Concrete To Ftt Clamp Below Grade Entry (@100mm Or 4")
04103-4 VDC4 In Concrete To Ftt Clamp Below Grade Entry (@100mm Or 4")
04104-1 VDC1 In Concrete To Ftt Clamp With Exposed Conduit Above Grade Entry (@100mm Or 4")
04104-4 VDC4 In Concrete To Ftt Clamp With Exposed Conduit Above Grade Entry (@100mm Or 4")
04109-1 VDC1 In Concrete To Ftt Clamp With Exposed Conduit Above Grade (@100mm Or 4")
04109-4 VDC4 In Concrete To Ftt Clamp With Exposed Conduit Above Grade (@100mm Or 4")
04110-4 VDC4 In Concrete To Ftt Clamp With Exposed Conduit Above Grade (@100mm Or 4")
04201-1 VDC1 In Soil To Ftt Clamp With Unexposed Core Above Grade Entry (@230mm Or 9")
04201-4 VDC4 In Soil To Ftt Clamp With Unexposed Core Above Grade Entry (@230mm Or 9")
04202-1 VDC1 In Soil To Ftt Clamp With Wall Cut Above Grade Entry (@230mm Or 9")
04202-4 VDC4 In Soil To Ftt Clamp With Wall Cut Above Grade Entry (@230mm Or 9")
04203-1 VDC1 In Soil To Ftt Clamp Below Grade Entry (@230mm Or 9")
04203-4 VDC4 In Soil To Ftt Clamp Below Grade Entry (@230mm Or 9")
04204-1 VDC1 In Soil To Ftt Clamp With Exposed Conduit Above Grade Entry (@230mm Or 9")
04204-4 VDC4 In Soil To Ftt Clamp With Exposed Conduit Above Grade Entry (@230mm Or 9")
04209-1 VDC1 In Soil To Ftt Clamp With Exposed Conduit Above Grade Entry (@230mm Or 9")
04209-4 VDC4 In Soil To Ftt Clamp With Exposed Conduit Above Grade Entry (@230mm Or 9")
   
5000 Series - Cans & Pullboxes: 5000 - Cans
05001-0 Can Placement In Soil
05002-0 Can Placement In Concrete
05003-0 Can Placement In Asphalt
05004-0 Can Placement And Transition To Manhole
05005-0 VDC To Manhole Transition
05006-0 VDC Transition To T266 Service Box
05007-0 VDC Transition To Generic Handhole
05008-0 VDC Transition To 2329 Catv Service Box
05009-0 VDC Transition To Existing Traditional Vault
05010-4 VDC4 Transition To Handhole 17"X30"X24"
   
6000 Series - Transitions: 6000 - Transitions
06001-0 Exposed Retaining Wall Transition
06003-0 Curb Transition In Concrete Curb & Gutter
06004-0 VDC To Ftt To Utility Pole Transition
06005-0 Exposed Bridge Face Transition In Soil
06006-0 Exposed Bridge Transition On Handrail
06007-0 Exposed Bridge Transition On Bridge Face
06009-0 Street Crossing W/Directional Bore
06010-0 Above Grade VDC To Riser Pole Transition
06011-0 VDC Transition To T266 Service Box
06012-0 Railway Crossing W/Directional Bore Post Can Installation
   
Unsorted and Misc. Deployment Details:
12in in soft VDC4 & VDC1
Two VDC1 in 6in cover in asphalt – cold asphalt only
Two VDC1 in 6in cover in asphalt
VDC1 6in cover in asphalt – cold asphalt only
VDC1&4 6in cover in asphalt
VDC1&4 6in cover in asphalt – cold asphalt only
VDC direct install into a vault

Jump to Top Index